Fluke MET/CAL Procedure ============================================================================= INSTRUMENT: Advantest TR6847: CAL ADJ /5500 DATE: 21-Aug-97 AUTHOR: Fluke Corporation REVISION: $Revision: 1.6 $ ADJUSTMENT THRESHOLD: 70% NUMBER OF TESTS: 69 NUMBER OF LINES: 543 CONFIGURATION: Fluke 5500A ============================================================================= # # Compatibility: # 5500/CAL 4.0 or MET/CAL 4.0 or later. # # Subprocedures: # None # # Required Files: # None # # System Specifications: # TUR calculation is based on specification interval of the accuracy file. # The default 5500A accuracy file contains 90 day specs. # # Fluke makes no warranty, expressed or implied, as to the fitness # or suitability of this procedure in the customer's application. # STEP FSC RANGE NOMINAL TOLERANCE MOD1 MOD2 3 4 CON 1.001 DISP {Procedure not formally tested with UUT.} 1.001 DISP {See procedure README file.} 1.002 ASK- P F V 1.003 ASK+ K X 1.004 HEAD PRELIMINARY INSTRUCTIONS 1.005 DISP Warm-up time: 30 min. - REQUIRED 1.005 DISP Temperature : 18 - 28 degC 1.005 DISP Humidity : <85% 1.006 HEAD [32] WARNING! 1.007 DISP HIGH VOLTAGE is used or exposed during the performance 1.007 DISP of this CAL. DEATH ON CONTACT may result if 1.007 DISP personnel fail to observe safety precautions. 1.008 HEAD CAL MODE SETUP 1.009 DISP Press the CAL ON switch located on the bottom face 1.009 DISP of the TR6847 body. Flashing of the display indicates 1.009 DISP that the UUT has been set in the CAL Mode. 1.010 HEAD {DC VOLTS ZERO POINT CAL} 1.011 DISP Select V DC. 1.012 DISP Connect the 5500A to the UUT as follows: 1.012 DISP [32] 5500A NORMAL HI to UUT V/Ohm 1.012 DISP [32] 5500A NORMAL LO to UUT COM 1.013 DISP During CAL, the display shows dashes. As 1.013 DISP CAL completes, the displayed digits begin to 1.013 DISP flash again. This indicates that CAL of this 1.013 DISP range is complete. 1.014 HEAD DC VOLTS ZERO POINT CAL: {30mV Range} 1.015 DISP Select the 30mV range. 1.016 5500 0mV S 2W 1.017 MESS Press SHIFT. 1.017 MESS Press DOWN or UP to change digit to "0". 1.017 MESS Press AUTO to switch to next digit. 1.017 MESS Set all digits to "0". 1.017 MESS 1.017 MESS Press SHIFT to initiate calibration. 1.017 MESS 1.018 EVAL Was calibration successful? 2.001 HEAD DC VOLTS ZERO POINT CAL: {300mV Range} 2.002 DISP Select the 300mV Range. 2.003 5500 0mV S 2W 2.004 EVAL Was calibration successful? 3.001 HEAD DC VOLTS ZERO POINT CAL: {3000mV Range} 3.002 DISP Select the 3000mV Range. 3.003 5500 0mV S 2W 3.004 EVAL Was calibration successful? 4.001 HEAD DC VOLTS ZERO POINT CAL: {30V Range} 4.002 DISP Select the 30V Range. 4.003 5500 0mV S 2W 4.004 EVAL Was calibration successful? 5.001 HEAD DC VOLTS ZERO POINT CAL: {300V Range} 5.002 DISP Select the 300V Range. 5.003 5500 0mV S 2W 5.004 EVAL Was calibration successful? 6.001 HEAD DC VOLTS ZERO POINT CAL: {1000V Range} 6.002 DISP Select the 1000V Range. 6.003 5500 0mV S 2W 6.004 EVAL Was calibration successful? 7.001 HEAD {DC VOLTS FULL SCALE CAL} 7.002 HEAD DC VOLTS FULL SCALE CAL: {3000mV Range} 7.003 DISP Select the 3000mV Range. 7.004 5500 3000mV S 2W 7.005 MEM2 =mV 7.006 MESS Press SHIFT. 7.006 MESS Set display to read [MEM1][MEM2]. 7.006 MESS (Press DOWN or UP to change digit, press AUTO 7.006 MESS to switch to next digit). 7.006 MESS 7.006 MESS Press SHIFT to initiate calibration. 7.006 MESS 7.007 EVAL Was calibration successful? 8.001 5500 -3000mV S 2W 8.002 EVAL Was calibration successful? 9.001 HEAD DC VOLTS FULL SCALE CAL: {30mV Range} 9.002 DISP Select the 30mV Range. 9.003 5500 30mV S 2W 9.004 EVAL Was calibration successful? 10.001 HEAD DC VOLTS FULL SCALE CAL: {300mV Range} 10.002 DISP Select the 300mV Range. 10.003 5500 300mV S 2W 10.004 EVAL Was calibration successful? 11.001 HEAD DC VOLTS FULL SCALE CAL: {30V Range} 11.002 DISP Select the 30V Range. 11.003 5500 30V S 2W 11.004 MEM2 =V 11.005 EVAL Was calibration successful? 12.001 HEAD DC VOLTS FULL SCALE CAL: {300V Range} 12.002 DISP Select the 300V Range. 12.003 5500 300V S 2W 12.004 EVAL Was calibration successful? 13.001 HEAD DC VOLTS FULL SCALE CAL: {1000V Range} 13.002 DISP Select the 1000V Range. 13.003 5500 1000V S 2W 13.004 EVAL Was calibration successful? 14.001 HEAD {DC LOW CURRENT ZERO POINT CAL} 14.002 DISP Select A DC 14.003 DISP Connect the 5500A to the UUT as follows: 14.003 DISP [32] 5500A AUX HI to UUT mA/uA 14.003 DISP [32] 5500A AUX LO to UUT COM 14.003 DISP [32] 5500A NORMAL HI to UUT mA/uA 14.003 DISP [32] 5500A NORMAL LO to UUT COM 14.004 HEAD DC LOW CURRENT ZERO POINT CAL: {300uA Range} 14.005 DISP Select the 300uA Range. 14.006 5500 0Z S CW 14.007 MESS Press SHIFT. 14.007 MESS Press DOWN or UP to change digit to "0". 14.007 MESS Press AUTO to switch to next digit. 14.007 MESS Set all digits to "0". 14.007 MESS 14.007 MESS Press SHIFT to initiate calibration. 14.007 MESS 14.008 EVAL Was calibration successful? 15.001 HEAD DC LOW CURRENT ZERO POINT CAL: {3000uA Range} 15.002 DISP Select the 3000uA Range. 15.003 5500 0Z S CW 15.004 EVAL Was calibration successful? 16.001 HEAD DC LOW CURRENT ZERO POINT CAL: {30mA Range} 16.002 DISP Select the 30mA Range. 16.003 5500 0Z S CW 16.004 EVAL Was calibration successful? 17.001 HEAD DC LOW CURRENT ZERO POINT CAL: {300mA Range} 17.002 DISP Select the 300mA Range. 17.003 5500 0Z S CW 17.004 EVAL Was calibration successful? 18.001 HEAD {DC LOW CURRENT FULL SCALE POINT CAL} 18.002 DISP Connect the 5500A to the UUT as follows: 18.002 DISP [32] 5500A AUX HI to UUT mA/uA 18.002 DISP [32] 5500A AUX LO to UUT COM 18.003 HEAD DC LOW CURRENT FULL SCALE POINT CAL: {300uA Range} 18.004 DISP Select the 300uA Range. 18.005 5500 300uA S 2W 18.006 MEM2 =uA 18.007 MESS Press SHIFT. 18.007 MESS Set display to read [MEM1][MEM2]. 18.007 MESS (Press DOWN or UP to change digit, press AUTO 18.007 MESS to switch to next digit). 18.007 MESS 18.007 MESS Press SHIFT to initiate calibration. 18.007 MESS 18.008 EVAL Was calibration successful? 19.001 HEAD DC LOW CURRENT FULL SCALE POINT CAL: {3mA Range} 19.002 DISP Select the 3mA Range. 19.003 5500 3mA S 2W 19.004 MEM2 =mA 19.005 EVAL Was calibration successful? 20.001 HEAD DC LOW CURRENT FULL SCALE POINT CAL: {30mA Range} 20.002 DISP Select the 30mA Range. 20.003 5500 30mA S 2W 20.004 EVAL Was calibration successful? 21.001 HEAD DC LOW CURRENT FULL SCALE POINT CAL: {300mA Range} 21.002 DISP Select the 300mA Range. 21.003 5500 300mA S 2W 21.004 EVAL Was calibration successful? 22.001 HEAD {DC HIGH CURRENT ZERO POINT CAL} 22.002 DISP Connect the 5500A to the UUT as follows: 22.002 DISP [32] 5500A NORMAL HI to UUT 10A 22.002 DISP [32] 5500A NORMAL LO to UUT COM 22.003 HEAD DC HIGH CURRENT ZERO POINT CAL: {3A Range} 22.004 DISP Select the 3A Range. 22.005 5500 0Z S 2W 22.006 MESS Press SHIFT. 22.006 MESS Press DOWN or UP to change digit to "0". 22.006 MESS Press AUTO to switch to next digit. 22.006 MESS Set all digits to "0". 22.006 MESS 22.006 MESS Press SHIFT to initiate calibration. 22.006 MESS 22.007 EVAL Was calibration successful? 23.001 HEAD DC HIGH CURRENT ZERO POINT CAL: {10A Range} 23.002 DISP Select the 10A Range. 23.003 5500 0Z S 2W 23.004 EVAL Was calibration successful? 24.001 HEAD {DC HIGH CURRENT FULL SCALE CAL} 24.002 DISP Connect the 5500A to the UUT as follows: 24.002 DISP [32] 5500A AUX HI to UUT 10A 24.002 DISP [32] 5500A AUX LO to UUT COM 24.003 HEAD DC HIGH CURRENT FULL SCALE CAL: {3A Range} 24.004 DISP Select the 3A Range. 24.005 5500 3A S 2W 24.006 MEM2 =A 24.007 MESS Press SHIFT. 24.007 MESS Set display to read [MEM1][MEM2]. 24.007 MESS (Press DOWN or UP to change digit, press AUTO 24.007 MESS to switch to next digit). 24.007 MESS 24.007 MESS Press SHIFT to initiate calibration. 24.008 EVAL Was calibration successful? 25.001 HEAD DC HIGH CURRENT FULL SCALE CAL: {10A Range} 25.002 DISP Select the 10A Range. 25.003 5500 10A S 2W 25.004 EVAL Was calibration successful? 26.001 HEAD {OHM ZERO POINT CALIBRATION} 26.002 DISP Select Ohms. 26.003 DISP Connect the 5500A to the UUT as follows: 26.003 DISP [32] 5500A AUX HI to UUT V/Ohm 26.003 DISP [32] 5500A AUX LO to UUT COM 26.003 DISP [32] 5500A NORMAL HI to UUT V/Ohm 26.003 DISP [32] 5500A NORMAL LO to UUT COM 26.004 HEAD OHM ZERO POINT CALIBRATION: {30 Ohm Range} 26.005 DISP Select the 30 Ohm Range. 26.006 5500 0Z S CW 26.007 MESS Press SHIFT. 26.007 MESS Press DOWN or UP to change digit to "0". 26.007 MESS Press AUTO to switch to next digit. 26.007 MESS Set all digits to "0". 26.007 MESS 26.007 MESS Press SHIFT to initiate calibration. 26.007 MESS 26.008 EVAL Was calibration successful? 27.001 HEAD OHM ZERO POINT CALIBRATION: {300 Ohm Range} 27.002 DISP Select the 300 Ohm Range. 27.003 5500 0Z S CW 27.004 EVAL Was calibration successful? 28.001 HEAD OHM ZERO POINT CALIBRATION: {3000 Ohm Range} 28.002 DISP Select the 3000 Ohm Range. 28.003 5500 0Z S CW 28.004 EVAL Was calibration successful? 29.001 HEAD OHM ZERO POINT CALIBRATION: {30 kOhm Range} 29.002 DISP Select the 30 kOhm Range. 29.003 5500 0kZ S CW 29.004 EVAL Was calibration successful? 30.001 HEAD OHM ZERO POINT CALIBRATION: {300 kOhm Range} 30.002 DISP Select the 300 kOhm Range. 30.003 5500 0kZ S CW 30.004 EVAL Was calibration successful? 31.001 HEAD OHM ZERO POINT CALIBRATION: {3000 kOhm Range} 31.002 DISP Select the 3000 kOhm Range. 31.003 5500 0kZ S CW 31.004 EVAL Was calibration successful? 32.001 HEAD OHM ZERO POINT CALIBRATION: {30 MOhm Range} 32.002 DISP Select the 30 MOhm Range. 32.003 5500 0MZ S CW 32.004 EVAL Was calibration successful? 33.001 HEAD OHM ZERO POINT CALIBRATION: {300 MOhm Range} 33.002 DISP Select the 300 MOhm Range. 33.003 5500 0MZ S CW 33.004 EVAL Was calibration successful? 34.001 HEAD {LP OHM ZERO POINT CALIBRATION} 34.002 DISP Select LP Ohms 34.003 HEAD LP OHM ZERO POINT CALIBRATION: {300 Ohm Range} 34.004 DISP Select the 300 Ohm Range. 34.005 5500 0Z S CW 34.006 EVAL Was calibration successful? 35.001 HEAD LP OHM ZERO POINT CALIBRATION: {3000 Ohm Range} 35.002 DISP Select the 3000 Ohm Range. 35.003 5500 0Z S CW 35.004 EVAL Was calibration successful? 36.001 HEAD LP OHM ZERO POINT CALIBRATION: {30 kOhm Range} 36.002 DISP Select the 30 kOhm Range. 36.003 5500 0kZ S CW 36.004 EVAL Was calibration successful? 37.001 HEAD LP OHM ZERO POINT CALIBRATION: {300 kOhm Range} 37.002 DISP Select the 300 kOhm Range. 37.003 5500 0kZ S CW 37.004 EVAL Was calibration successful? 38.001 HEAD LP OHM ZERO POINT CALIBRATION: {3000 kOhm Range} 38.002 DISP Select the 3000 kOhm Range. 38.003 5500 0kZ S CW 38.004 EVAL Was calibration successful? 39.001 HEAD LP OHM ZERO POINT CALIBRATION: {30 MOhm Range} 39.002 DISP Select the 30 MOhm Range. 39.003 5500 0MZ S CW 39.004 EVAL Was calibration successful? 40.001 HEAD {LP OHM FULL SCALE CALIBRATION} 40.002 HEAD LP OHM FULL SCALE CALIBRATION: {300 Ohm Range} 40.003 DISP Select the 300 Ohm Range. 40.004 5500 300Z S CW 40.005 MEM2 = Ohms 40.006 MESS Press SHIFT. 40.006 MESS Set display to read [MEM1][MEM2]. 40.006 MESS (Press DOWN or UP to change digit, press AUTO 40.006 MESS to switch to next digit). 40.006 MESS 40.006 MESS Press SHIFT to initiate calibration. 40.006 MESS 40.007 EVAL Was calibration successful? 41.001 HEAD LP OHM FULL SCALE CALIBRATION: {3000 Ohm Range} 41.002 DISP Select the 3000 Ohm Range. 41.003 5500 3000Z S CW 41.004 EVAL Was calibration successful? 42.001 HEAD LP OHM FULL SCALE CALIBRATION: {30 kOhm Range} 42.002 DISP Select the 30 kOhm Range. 42.003 5500 30kZ S CW 42.004 MEM2 = kOhms 42.005 EVAL Was calibration successful? 43.001 HEAD LP OHM FULL SCALE CALIBRATION: {300 kOhm Range} 43.002 DISP Connect the 5500A to the UUT as follows: 43.002 DISP [32] 5500A NORMAL HI to UUT V/Ohm 43.002 DISP [32] 5500A NORMAL LO to UUT COM 43.003 DISP Select the 300 kOhm Range. 43.004 5500 300kZ S 2W 43.005 EVAL Was calibration successful? 44.001 HEAD LP OHM FULL SCALE CALIBRATION: {3000 kOhm Range} 44.002 DISP Select the 3000 kOhm Range. 44.003 5500 3000kZ S 2W 44.004 EVAL Was calibration successful? 45.001 HEAD LP OHM FULL SCALE CALIBRATION: {30 MOhm Range} 45.002 DISP Select the 30 MOhm Range. 45.003 5500 30MZ S 2W 45.004 MEM2 = MOhms 45.005 EVAL Was calibration successful? 46.001 HEAD {OHM FULL SCALE CALIBRATION} 46.002 DISP Select LP Ohms 46.003 DISP Connect the 5500A to the UUT as follows: 46.003 DISP [32] 5500A AUX HI to UUT V/Ohm 46.003 DISP [32] 5500A AUX LO to UUT COM 46.003 DISP [32] 5500A NORMAL HI to UUT V/Ohm 46.003 DISP [32] 5500A NORMAL LO to UUT COM 46.004 HEAD OHM FULL SCALE CALIBRATION: {30 Ohm Range} 46.005 DISP Select the 30 Ohm Range. 46.006 5500 30Z S CW 46.007 MEM2 = Ohms 46.008 EVAL Was calibration successful? 47.001 HEAD OHM FULL SCALE CALIBRATION: {300 Ohm Range} 47.002 DISP Select the 300 Ohm Range. 47.003 5500 300Z S CW 47.004 EVAL Was calibration successful? 48.001 HEAD OHM FULL SCALE CALIBRATION: {3000 Ohm Range} 48.002 DISP Select the 3000 Ohm Range. 48.003 5500 3000Z S CW 48.004 EVAL Was calibration successful? 49.001 HEAD OHM FULL SCALE CALIBRATION: {30 kOhm Range} 49.002 DISP Select the 30 kOhm Range. 49.003 5500 30kZ S CW 49.004 MEM2 = kOhms 49.005 EVAL Was calibration successful? 50.001 HEAD OHM FULL SCALE CALIBRATION: {300 kOhm Range} 50.002 DISP Connect the 5500A to the UUT as follows: 50.002 DISP [32] 5500A NORMAL HI to UUT V/Ohm 50.002 DISP [32] 5500A NORMAL LO to UUT COM 50.003 DISP Select the 300 kOhm Range. 50.004 5500 300kZ S 2W 50.005 EVAL Was calibration successful? 51.001 HEAD OHM FULL SCALE CALIBRATION: {3000 kOhm Range} 51.002 DISP Select the 3000 kOhm Range. 51.003 5500 3000kZ S 2W 51.004 EVAL Was calibration successful? 52.001 HEAD OHM FULL SCALE CALIBRATION: {30 MOhm Range} 52.002 DISP Select the 30 MOhm Range. 52.003 5500 30MZ S 2W 52.004 MEM2 = MOhms 52.005 EVAL Was calibration successful? 53.001 HEAD OHM FULL SCALE CALIBRATION: {300 MOhm Range} 53.002 DISP Select the 300 MOhm Range. 53.003 5500 300MZ S 2W 53.004 EVAL Was calibration successful? 54.001 HEAD {+/- F.S. & +/- 1/10th F.S. AC+DC CALIBRATION} 54.002 DISP Press the CAL ON switch located on the bottom face 54.002 DISP of the UUT body to cancel the Calibration Mode. 54.002 DISP 54.002 DISP Turn OFF the Power Switch. 54.002 DISP 54.002 DISP While pressing the AC+DC key, turn ON Power Switch. 54.003 DISP The following +/- Full Scale and +/- 1/10th Full Scale 54.003 DISP adjustments are interactive, therefore their adjustment 54.003 DISP may require repeating. 54.004 5500 3V S 2W 54.005 MEMI Enter UUT reading in volts. 54.006 MATH MEM1 = MEM - M[1] 54.007 JMPZ 54.017 0.001U 54.008 MATH M[1] = MEM 54.009 5500 -3V S 2W 54.010 DISP Turn the +/- full scale adjusting potentiometer 54.010 DISP until the display is equal to -[MEM]. 54.011 5500 0.3V S 2W 54.012 MEMI Enter UUT reading in volts. 54.013 MATH M[2] = MEM 54.014 5500 -0.3V S 2W 54.015 DISP Turn the +/- 1/10th full scale adjusting potentiometer 54.015 DISP until the display is equal -[MEM]. 54.016 JMP 54.004 54.017 5500 * S 54.018 RSLT =+/- Full Scale adjustment was performed 54.019 RSLT =+/- 1/10th Full Scale adjustment was performed 54.020 HEAD {ZERO POINT ADJUSTMENT OF RANGING AMPLIFIER} 54.021 DISP Set the UUT to the AC+DC mode of AC Voltage 54.021 DISP measurement function, and set the range to 300 mV. 54.022 DISP During the following adjustment, the meter will measure 54.022 DISP +300 mV and -300 mV alternatly every 3 seconds. 54.022 DISP While input is alternating, adjust RAZ potentiometer 54.022 DISP (located on side of the meter) until the difference 54.022 DISP in the + and - reading is at a minimum. 54.022 DISP The input will alternate a total of 6 times. 54.022 DISP 54.022 DISP Press ADV to continue. 54.023 MATH M[1] = 5 54.024 5500 300mV S 2W 54.025 HEAD [7]ZERO POINT ADJUSTMENT OF RANGING AMPLIFIER[D3000] 54.026 5500 -300mV S 2W 54.027 HEAD [7]ZERO POINT ADJUSTMENT OF RANGING AMPLIFIER[D3000] 54.028 MATH MEM1 = M[1] 54.029 JMPZ 54.032 0.1U 54.030 MATH M[1] = M[1] - 1 54.031 JMP 54.024 54.032 5500 * S 54.033 OPBR Was RAZ adjusted for minimum reading difference? 54.034 JMPT 54.037 54.035 DISP Input will alternate again from +300 mV to -300 mV. 54.035 DISP 54.035 DISP Adjust RAZ for minimum reading difference. 54.036 JMP 54.023 54.037 RSLT =Zero Point adjustment of ranging amp (RAZ) was adjusted 54.038 HEAD {AC FREQUENCY CHARACTERISTICS ADJUSTMENT} 54.039 DISP Select V AC. 54.040 DISP Select the 3000mV Range. 54.041 5500 3000mV 70kH SI S 2W 54.042 DISP Adjust the HFFS potentiometer (located on left side face 54.042 DISP of the equipment) so that the display value is 54.042 DISP 3000.0 mV +/-15 counts. 54.043 EVAL Was {HFFS adjusted for 3000.0 mV +/-15 counts}? 55.001 HEAD {AC VOLTAGE (TRUE RMS) ADJUSTMENT} 55.002 DISP During CAL, the digits will flash. When calibration is 55.002 DISP complete the display will read the correct value. 55.003 HEAD AC VOLTAGE (TRUE RMS) ADJUSTMENT: {3000mV Range} 55.004 DISP Set the CAL ON switch to ON (located on bottom). 55.005 RSLT =Full Scale 55.006 5500 3000mV 1kH SI S 2W 55.007 MESS Wait for display to stabilize, then press SHIFT to 55.007 MESS initiate calibration. 55.008 EVAL Was calibration successful? 56.001 RSLT =1/10th Full Scale 56.002 MATH MEM = MEM1 / 10 56.003 5500 mV 1kH SI S 2W 56.004 DISP Press SHIFT. 56.004 DISP 56.004 DISP Press the UP or Down keys until the display is [MEM]mV. 56.005 HEAD DELAYING 6 SECONDS[D6000] 56.006 EVAL Was calibration successful? 57.001 HEAD AC VOLTAGE (TRUE RMS) ADJUSTMENT: {30V Range} 57.002 DISP Select the 30V Range. 57.003 5500 30V 1kH SI S 2W 57.004 EVAL Was calibration successful? 58.001 HEAD AC VOLTAGE (TRUE RMS) ADJUSTMENT: {300V Range} 58.002 DISP Select the 300V Range. 58.003 5500 300V 1kH SI S 2W 58.004 EVAL Was calibration successful? 59.001 HEAD AC VOLTAGE (TRUE RMS) ADJUSTMENT: {750V Range} 59.002 DISP Select the 750V Range. 59.003 RSLT =Full Scale 59.004 5500 750V 1kH SI S 2W 59.005 EVAL Was calibration successful? 60.001 RSLT =1/10th Full Scale 60.002 MATH MEM = MEM1 / 10 60.003 5500 V 1kH SI S 2W 60.004 DISP Press SHIFT. 60.004 DISP 60.004 DISP Press the UP or Down keys until the display is [MEM]V. 60.005 HEAD DELAYING 6 SECONDS[D6000] 60.006 EVAL Was calibration successful? 61.001 HEAD {AC LOW CURRENT CALIBRATION} 61.002 DISP Select A AC 61.003 DISP Connect the 5500A to the UUT as follows: 61.003 DISP [32] 5500A AUX HI to UUT mA/uA 61.003 DISP [32] 5500A AUX LO to UUT COM 61.004 HEAD AC LOW CURRENT CALIBRATION: {3000uA Range} 61.005 DISP Select the 3000uA Range. 61.006 RSLT =Full Scale 61.007 5500 3000uA 300H SI S 2W 61.008 EVAL Was calibration successful? 62.001 RSLT =1/10th Full Scale 62.002 MATH MEM = MEM1 / 10 62.003 5500 uA 300H SI S 2W 62.004 DISP Press SHIFT. 62.004 DISP 62.004 DISP Press the UP or Down keys until the display is [MEM]uA. 62.005 EVAL Was calibration successful? 63.001 HEAD AC LOW CURRENT CALIBRATION: {300uA Range} 63.002 DISP Select the 300uA Range. 63.003 5500 300uA 300H SI S 2W 63.004 EVAL Was calibration successful? 64.001 HEAD AC LOW CURRENT CALIBRATION: {30mA Range} 64.002 DISP Select the 30mA Range. 64.003 5500 30mA 300H SI S 2W 64.004 EVAL Was calibration successful? 65.001 HEAD AC LOW CURRENT CALIBRATION: {300mA Range} 65.002 DISP Select the 300mA Range. 65.003 5500 300mA 300H SI S 2W 65.004 EVAL Was calibration successful? 66.001 HEAD {AC HIGH CURRENT CALIBRATION} 66.002 DISP Connect the 5500A to the UUT as follows: 66.002 DISP [32] 5500A AUX HI to UUT 10A 66.002 DISP [32] 5500A AUX LO to UUT COM 66.003 HEAD AC HIGH CURRENT CALIBRATION: {3A Range} 66.004 DISP Select the 3A Range. 66.005 5500 3A 300H SI S 2W 66.006 EVAL Was calibration successful? 67.001 HEAD AC HIGH CURRENT CALIBRATION: {10A Range} 67.002 DISP Select the 10A Range. 67.003 RSLT =Full Scale 67.004 5500 10A 300H SI S 2W 67.005 EVAL Was calibration successful? 68.001 RSLT =1/10th Full Scale 68.002 MATH MEM = MEM1 / 10 68.003 5500 A 300H SI S 2W 68.004 DISP Press SHIFT. 68.004 DISP 68.004 DISP Press the UP or Down keys until the display is [MEM]A. 68.005 EVAL Was calibration successful? 69.001 END